beautypg.com

0x2d41, Ilc _1, 0x2d42 – Burkert Type 8746 User Manual

Page 23: Ilc _2, Ensor, Ktor, Odul description of initiation files eds

background image

S

ensor

A

ktor

M

odul

Description of initiation files EDS

Description_of_InitiationFilesEDS_2

Version 1.4

page 21 / 27

sub name

description

ac

ce

ss

type

flags

accessrights

im

p

o

rt

Im

p

o

rt

d

e

vID

S

IM

-C

a

rd

R

-

u

se

r

W

-

u

se

r

R

-

a

d

v.

u

s

e

r

W

-

a

d

v.

u

se

r

R

-

in

sta

ll

e

r

W

-

ins

ta

lle

r

R

-

b

u

e

rke

rt

W

-

b

u

e

rke

rt

1 Operation Mode

Voltage reference for sensor (TP3/Bandgap)
See attachment:

SFS7011 operation mode

RO

- - - - x - x x

2 Gain

Gain for the sensor value

RO

- - - - x - x x

3 Multiplexer

Connection of thermopiles (difference, sum, etc.)
See attachment:

SFS7011 heaterSFS7011 multiplexer

RO

- - - - x - x x

4 Heaterpower

Electrical power of the heater
See attachment:

SFS7011 heater

RO

- - - - x - x x

5 Error Code

Sensor specific error code
0: no error occured

RO

- - - - x - x -


Error Codes:
ui16ErrorCode|=0x0001; // not able to write the factory settings
ui16ErrorCode|=0x0002; // sensor will run with the default resolution of 9 bit!
ui16ErrorCode|=0x0004; // Wrong user data!
ui16ErrorCode|=0x0008; // No measurement triggered!
ui16ErrorCode|=0x0010; // CRC error!
ui16ErrorCode|=0x0020; // Could not read data from sensor
ui16ErrorCode|=0x0080; // No communication interface available!

0x2D41

ILC _1

0x2D42

ILC _2

Detailed information see attachement: General Description of flow sensor.

sub name

description

ac

ce

ss

type

flags

accessrights

im

p

o

rt

Im

p

o

rt

d

e

vID

S

IM

-C

a

rd

R

-

u

se

r

W

-

u

se

r

R

-

a

d

v.

u

s

e

r

W

-

a

d

v.

u

se

r

R

-

in

sta

ll

e

r

W

-

ins

ta

lle

r

R

-

b

u

e

rke

rt

W

-

b

u

e

rke

rt

1 Diag Channel

Channel no. which is converted for diagnose purposes

RO

- - - - x - x x

2 Raw Diag Ch

Value of diagnose channel chosen above

RO

- - - - x - x x

3 Gain Ch0

Gain setting for adc ch0

RO

- - - - x - x x

4 Gain Ch1

Gain setting for adc ch1

RO

- - - - x - x x

5 Gain Diag

Gain setting for diagnose channel

RO

- - - - x - x x

6 GPIO Status

Status of the available gpio pins (set/reset)

RO

- - - - x - x x

7 Regression Line Offset Offset modification for temperature compensation

RO

- - - - x - x x

8 Error Code

Sensor specific error code
0: no error occured

RO

- - - - x - x -


Error Codes: unused.