Technical data – Burkert Type 8640 User Manual
Page 7

7
Technical data
5. TECHNICAL DATA
5.1. Conformity
The AirLINE system Type 8640 conforms with the EC Directives
according to the EC Declaration of Conformity.
5.2. Standards
The applied standards, which verify conformity with the EC Direc-
tives, can be found on the EC-Type Examination Certificate and / or
the EC Declaration of Conformity.
5.3. General Technical Data
Technical Data
Pilot valve type 0460,
6524, 6525
Pilot valve type 0461,
6526, 6527
Pressure range
Vac.
up to
10 bar
Vac.
up to
10 bar
Operating
voltage
24 V DC
24 V DC
Voltage tolerance
± 10 %
± 10 %
Ambient
temperature
0 ... +55 °C
(
when using Type
0460 and 0461: 0 ... +50 °C)
5.3.1. Rating plate
MADE IN GERMAN
Y
W14UN
450000Y
24 V DC 1W
PN 2,5 - 7 bar
6525 H 4,0
Type
Operating principle
Orifice
Identification number
Voltage (± 10 %), capacity
Pressure range
Fig. 1:
Location and description of the rating plate
english
Type 8640
- Type 0125 (15 pages)
- Type 0121 (4 pages)
- Type 0331 (4 pages)
- Type 6012 (4 pages)
- Type 0330 (2 pages)
- Type 0127 (18 pages)
- Type 0131 (5 pages)
- Type 0141 (5 pages)
- Type 0142 (12 pages)
- Type 0145 (3 pages)
- Type 0174 (5 pages)
- Type 0212 (2 pages)
- Type 0211 (5 pages)
- Type 0212-B (18 pages)
- Type 0250 (64 pages)
- Type 0253 (2 pages)
- Type 0255 (15 pages)
- Type 0355 (2 pages)
- Type 0255 (2 pages)
- Type 8006 (34 pages)
- Type 8640 (2 pages)
- Type 8640 (119 pages)
- Type 0256 (15 pages)
- Type 0256 (2 pages)
- Type 0258 (72 pages)
- Type 0262 (5 pages)
- Type 0273 (6 pages)
- Type 0280 (2 pages)
- Type 0280 (12 pages)
- Type 0280 (5 pages)
- Type 0281 (2 pages)
- Type 0282 (2 pages)
- Type 0283 (2 pages)
- Type 0286 (4 pages)
- Type 0287 (15 pages)
- Type 0290 (2 pages)
- Type 0290 (14 pages)
- Type 0293 (18 pages)
- Type 0300 (6 pages)
- Type 0301 (6 pages)
- Type 0312 (6 pages)
- Type 0311 (2 pages)
- Type 6519 (3 pages)
- Type 6519 (4 pages)