Maintenance, cleaning
DANGER!
Risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.
• Before removing a device, switch off the pressure and vent the lines.
WARNING!
Risk of injury if the wrong tools are used!
It is dangerous to use unsuitable tools for installation work as the
device may be damaged.
• To remove the actuator from the valve body, use an open-end
wrench, never a pipe wrench.
• To replace the packing gland, use a special installation wrench,
modified socket wrench or a socket wrench.
• Observe tightening torques.
Before the packing gland can be replaced, the actuator must be
removed from the valve body and the control cone removed.
Removing the actuator from the valve body
→
Clamp the valve body in a holding device
(applies only to valves which have not yet been installed).
NOTE!
Damage to the seat seal or the seat contour!
• When removing the actuator, ensure that the valve is in open
position.
→
Control function A:
Without unit control: pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
With unit control: open the valve according to the operating
instructions for the control unit.
Actuator
Nipple
Valve body
Flats for open-end
wrench
Pilot air port
Pilot air port 2
1
Fig. 28: Valve
→
Using a suitable open-end wrench, place the wrench flat on the pipe.
→
Unscrew the actuator from the valve body.