beautypg.com

Burkert Type 2300 User Manual

Page 33

background image

33

Maintenance, cleaning

1

2

Pilot air port

Fig. 27: Connections

Tightening torques of valve body / nipples
DN

Tightening torques [Nm]

15

45 ±3

20

50 ±3

25

60 ±3

32

65 ±3

40
50

70 ±3

65

100 ±3

Tab. 17: Tightening torques of valve body / nipples

If the position of the pilot air ports for installation of the
hoses is unfavorable, these can be aligned steplessly by
rotating the actuator through 360°.
The procedure is described in the chapter entitled “8.3.4.
Rotating the actuator”.

10.3.2. Replacing the packing gland

The seal set for the packing gland contains

SP10 / SP14

SP10

SP14

• 1 support ring
• 5 chevron seals
• 2 or 3 pressure rings

12)

• 1 pressure spring
• 1 graphite seal
• Lubricant

SP22
• 1 support ring
• 7 chevron seals
• 2 pressure rings
• 1 pressure spring
• 1 spacer
• 1 graphite seal
• Lubricant

Tab. 18: Seal set for packing gland

12)

depending on the spindle diameter (10 or 14 mm)

english

Type 2300