Burkert Type 2300 User Manual

Page 14

background image

14

Technical data

Maximum pilot pressure for valves
without pneumatic control unit

Actuator size Actuator material

max. permitted pilot
pressure

6)

ø 50 mm

PPS

10 bar

ø 70 mm
ø 90 mm
ø 130 mm

7 bar

Tab. 4: Pilot pressure for valves without pneumatic control unit

6)

Observe the maximum pressure range according to the
type label!

Operating pressure for control function A

7)

Actuator size

Orifice DN
[mm]

Required pilot
pressure [bar]

Max. sealed

medium

pressure [bar]

ø 50 mm

15

5.5

16

20

5.5

10

25

5.5

5

ø 70 mm

15

5.5

16

20

5.5

16

25

5.5

12

32

5.5

6

ø 90 mm

25

5.5

16

32

5.5

16

40

5.5

12

50

5.5

7

ø 130 mm

40

5.5

16

50

5.5

16

65

5.6

16

Tab. 5: Operating pressure for control function A

7)

The description of the control function (CF) can be found in
chapter entitled “6.2.1. Control functions (CF)”
.

english

Type 2300