beautypg.com

English – Burkert Type 2300 User Manual

Page 16

background image

16

Technical data

DN2

0

DN25

0

2

4

6

8

10

12

14

16

0

1

2

3

4

5

6

7

8

9

10

DN1

5

DN32

Pilot pressure [bar]

Medium

pressure

[bar]

ø 70 CFB

Fig. 4: Pressure graph, actuator ø 70 mm, control function B

DN3

2

DN50

0

2

4

6

8

10

12

14

16

0

1

2

3

4

5

6

7

8

9

10

DN2

5

DN4

0

Pilot pressure [bar]

Medium

pressure

[bar]

ø 90 CFB

Fig. 5: Pressure graph, actuator ø 90 mm, control function B

DN4

0

0

2

4

6

8

10

12

14

16

0

1

2

3

4

5

6

7

8

9

10

DN5

0

DN6

5

Pilot pressure [bar]

Medium

pressure

[bar]

ø 130 CFB

Fig. 6: Pressure graph, actuator ø 130 mm, control function B

english

Type 2300