Technical data

Flow values for DN65 - Actuator size ø 130

Stroke [%] Kv value [m

3

/h]

Stroke [%] Kv value [m

3

/h]

5

1.7

60

58.0

10

2.0

70

67.0

20

6.5

80

75.0

30

20.0

90

83.0

40

35.0

100

90.0

50

48.0

Tab. 15: Flow values for DN65 - Actuator size ø 130

Flow characteristics for DN65 - Actuator size ø 130

Stroke [%]

Kv

[m

3

/h

]

0

90
80
70
60
50
40
30
20

10

0

20

40

60

80

100

Fig. 15: Flow characteristics for DN65 - Actuator size ø 130

7.6.

General technical data

Control functions (CF) The valve seat is always closed against

the medium flow

Control function A

Normally closed by spring action

Control function B

Normally open by spring action

Control function I

Actuating function via reciprocal pressur-
ization
(not for actuator size ø 50 mm in combi-
nation with Type 8696)

Actuator sizes

ø 50 mm
ø 70 mm
ø 90 mm
ø 130 mm

Materials

Valve body

316L

Actuator

PPS and stainless steel

Sealing elements

FKM and EPDM

Spindle sealing

PTFE V rings with spring compensation

(with silicone grease)

Control cone

Control cone with PTFE seal
Steel / steel seal