beautypg.com

Burkert Type 2300 User Manual

Page 19

background image

19

Technical data

Flow values for DN40 - Actuator size ø 90

Stroke [%] Kv value [m

3

/h]

Stroke [%] Kv value [m

3

/h]

5

0.47

60

21.5

10

0.62

70

25.3

20

1.1

80

28.8

30

2.6

90

31.6

40

10.0

100

34.0

50

17.0

Tab. 11: Flow values for DN40 - Actuator size ø 90

Flow characteristics for DN40 - Actuator size ø 90

Stroke [%]

Kv

[m

3

/h

]

0

35

30

25

20

15

10

5

0

20

40

60

80

100

Fig. 11: Flow characteristics for DN40 - Actuator size ø 90

Flow values for DN40 - Actuator size ø 130

Stroke [%] Kv value [m

3

/h]

Stroke [%] Kv value [m

3

/h]

5

0.48

60

24.3

10

0.66

70

28.3

20

1.4

80

31.7

30

5.1

90

34.5

40

14.0

100

36.0

50

20.0

Tab. 12: Flow values for DN40 - Actuator size ø 130

Flow characteristics for DN40 - Actuator size ø 130

Stroke [%]

Kv

[m

3

/h

]

0

35

30

25

20
15

10

5

0

20

40

60

80

100

40

Fig. 12: Flow characteristics for DN40 - Actuator size ø 130

english

Type 2300