Repairs, Packaging, transport, storage – Burkert Type 2002 User Manual
Page 29
29
Repairs
Valve set SET 6 stainless steel body (2/2-way valve):
dn
Order no.
(ptfe seal)
Order no.
(fkm seal)
15
011 134
011 234
20
011 171
011 253
25
6)
011 202
011 259
25
7)
160 737
168 816
32
011 208
011 262
40
011 209
011 267
50
233 813
233 817
65
233 815
233 818
Tab. 15: SET 6 – stainless steel body
6)
Actuator size 50
7)
Actuator size 63
13.
repairs
Further information on repairs can be found in the mainte-
nance and repair instructions which are on the Internet:
office.
14.
packaging, transpOrt,
stOrage
note!
transport damages!
Inadequately protected equipment may be damaged during transport.
• During transportation protect the device against wet and dirt in
shock-resistant packaging.
• Avoid exceeding or dropping below the permitted storage
temperature.
incorrect storage may damage the device.
• Store the device in a dry and dust-free location!
• Storage temperature –20 … +65 °C.
damage to the environment caused by device components
contaminated with media.
• Observe applicable regulations on disposal and the environment.
• Observe national waste disposal regulations.
english