Assembly

8.3.2. installing the actuator (welded body)

Graphite seal

Fig. 20: Graphite seal

Check graphite seal and, if required, replace. Remove all
residues when replacing seal.

Warning!

danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen
applications there is a risk of an explosion!
• In specific applications, e.g. oxygen or analysis applications, use

appropriately authorized lubricants only.

Grease nipple thread before re-installing the actuator
(e.g. with Klüber paste UH1 96-402 from Klüber).

note!

damage to the seal on the swivel plate!
• When installing the actuator, ensure that the valve is in the open

position.

Control function A and I:
Pressurize lower control air connection with compressed air
(5 bar) so that the swivel plate is lifted off the valve seat and is
not damaged when screwed in.

Screw actuator into the valve body.

tightening torques:

Orifice

(dn)

tightening torque

(nm)

15

45 ± 3

20

50 ± 3

25

60 ± 3

32

65 ± 3

40

65 ± 3

50

70 ± 3

65

70 ± 3

Tab. 10: Tightening torques

If the body is stainless steel, grease the nipple thread with
e.g. Klüber paste UH1 96-402.