beautypg.com

Burkert Type 2002 User Manual

Page 14

background image

14

TechnicalData

7.5.3. Minimum control pressures

incoming flow below seat
(medium flow against the closing direction of the valve)
The required minimum control pressure P

min

for control function A is:

actuator size

[mm]

40

50

63

80

100

125

p

min

[bar]

4.0

3.9

4.5

5.0

4.4

3.2

The following graphs illustrate the required minimum control pressure
depending on the medium pressure for control functions B and I
(incoming flow below seat).

Control

pressure [bar]

Medium

pressure

[bar]

CFB / CFI, ø 40 mm

DN

15

DN

20

Fig. 8: Pressure graph, actuator ø 40 mm, control function B and I

Control

pressure [bar]

Medium

pressure

[bar]

CFB / CFI, ø 50 mm

DN

15

DN

20

DN

25

Fig. 9: Pressure graph, actuator ø 50 mm, control function B and I

Control

pressure [bar]

Medium

pressure

[bar]

CFB / CFI, ø 63 mm

DN

20

DN

32

DN

40

DN

50

DN

25

Fig. 10: Pressure graph, actuator ø 63 mm, control function B and I

english

Type 2000/2002

This manual is related to the following products: