beautypg.com

Operating conditions – Burkert Type 2002 User Manual

Page 13

background image

13

TechnicalData

7.5.

Operating conditions

7.5.1. temperature ranges

actuator

size

[mm]

actuator

material

temperature ranges

medium

(for ptfe seal)

environment

1)

40 - 63

PA

–10 ... see “Fig. 7”

–10 ... see “Fig. 7”

80 - 125

PA

–10 ... +180 °C

–10 ... +60 °C

40 - 80

PPS

–10 ... +180 °C

+5 ... +140 °C

100 - 125

PPS

–10 ... +180 °C

+5 ... +90 °C

2)

Tab. 5: Temperature ranges

1)

If a pilot valve is used, the max. ambient temperature
is + 55 °C

Medium
temperature [°C]

Ambient

temperature

[°C]

100

120

140

160

180

200

70

60

50

40

30

20

∅ 63

∅ 50

∅ 40

Fig. 7: Temperature range of the maximum medium and ambient

temperature for PA actuators

2)

* briefly up to max. 140 °C

7.5.2. pressure ranges

maximum control pressure 2/2-way and 3/2-way valve:

actuator

material

actuator size

[mm]

max. control pressure

[bar]

PA

40 - 80

10

125

7

PPS

40 - 80

10

125

7

Tab. 6: Maximum control pressure

maximum operating pressure 3/2-way valve, control function a:

Orifice
[mm]

actuator

size

[mm]

max. medium pressure up to
180 °c [bar] direction of flow

min.

control

pressure

[bar]

1 → 2

2 → 3, 2 → 1

15 - 20

50

11

16

4.4

63

16

16

4.7

25

63

10

16

4.9

32 - 40

80

9

16

6.0

125

14

16

3.4

50

125

10

16

4.3

Tab. 7: Max. operating pressure

For control function F the maximum permitted operating
pressure is 16 bar.

english

Type 2000/2002

This manual is related to the following products: