Assembly

media
Control medium

Neutral gases, air

Flow media

Water, alcohols, oils, fuels, hydraulic liquid,
saline solutions, lyes, organic solvents,
steam

connections

type 2000

angle seat valve

type 2002

3/2-way globe valve

Socket:
G 3/8 to G 2 1/2
(NPT on request)

G 1/2 to G 2

Welded connections:
in accordance with EN ISO 1127,
DIN 11850 R2
clamped connections:
in accordance with ISO 2852,
ASME BPE,
BS 4825

Tab. 9: Connections

Other connections on request.

installation position

any position, preferably with
actuator face up

8.

asseMBly

8.1.

safety instructions

Danger!

risk of injury from high pressure in the equipment!
• Before dismounting pneumatic lines or valves, turn off the pres-

sure and vent the lines.

Warning!

risk of injury from improper assembly!
• Installation may be carried out by authorized technicians only

and with the appropriate tools!

risk of injury from unintentional activation of the system and
an uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.

Warning!

for control function i – danger if control pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
• To ensure a controlled restart, first pressurize the device with

control pressure, then switch on the medium.