beautypg.com

Technical data, Conformity, Standards – Burkert Type 2002 User Manual

Page 12: Approvals, Type label

background image

12

TechnicalData

6.2.4. incoming flow above seat

The valve is closed by spring force (control function A, CFA) with
the medium flow. As the medium pressure is over the swivel plate, it
supports the closing process of the valve and also contributes to the
sealing of the valve seat.
The valve is opened by the control pressure.

Warning!

risk of injury from water hammer.
A water hammer could crack the lines and device.
• Use valves with flow inlet above seat for gaseous media and

steam only.

To ensure complete opening, the minimum control pressure
must be used!

Follow instructions for use in the Ex area! See chapter “3.1”.

Fig. 5: Incoming flow above seat (closing with medium)

7.

technical Data

7.1.

conformity

The angle seat valve type 2000 / globe valve type 2002 conforms
with the EC Directives according to the EC Declaration of Conformity.

7.2.

standards

The applied standards, which verify conformity with the EC Direc-
tives, can be found on the EC-Type Examination Certificate and / or
the EC Declaration of Conformity.

7.3.

approvals

The product is authorized for use in Zone 1 and 21 according to the
ATEX directive 94/9/EC of category 2 G/D.

Follow instructions for use in the Ex area! See chapter “3.1”.

7.4.

type label

Flow 1 2
2000 A 50,0 NBR RG

Made in Germany

00182076

W1X LU

G 2 P

med 16 bar

Pilot 1,6 - 10 bar

R

„R“ : variant

Type

Control pressure

Control function

Identification number

Direction of flow

Orifice

Seal material

Body material
Nominal pressure

Connection type

Fig. 6: Example of the type label

english

Type 2000/2002

This manual is related to the following products: