Carlon Structured Cable Management Systems Handbook - Low Res User Manual
Page 15

13
WHAT ABOUT THOSE
SMALL, CONFINED
AREAS WHERE IT IS
DIFFICULT TO USE A
HAMMER TO ATTACH
THE BRACKET TO THE
STUD?
Not only can Carlon’s low
voltage bracket be nailed
to the stud, it can also be
screwed in to the stud for
those confined areas.
(Screws not provided.)
Carlon also realizes that
not all construction consists
of wood studs.
Some constructions
consist of steel
studs. That same
bracket can be used
to attach the brack-
ets to steel studs.
Carlon’s 2-Gang
Low Voltage
Bracket also has
mounting holes for
4" square devices,
such as fire alarms.
4-Inch Square Device
Mounting Holes
Gross Automation (877) 268-3700 · www.carlonsales.com · [email protected]
See also other documents in the category Carlon Equipment:
- Adjustable Low Voltage Floor Bracket Kit - Low Res (4 pages)
- Bore-Gard 10 Reasons to Use (2 pages)
- Bore-Gard Cleveland Pull Force (1 page)
- Bore-Gard Cleveland (1 page)
- Bore-Gard Columbia (1 page)
- Bore-Gard Florence (1 page)
- Bore-Gard Indiana State Museum (1 page)
- Bore-Gard Long Island Pull Force (1 page)
- Bore-Gard Long Island, NY (1 page)
- Bore-Gard Perry, OK (1 page)
- Bore-Gard Statue of Liberty (1 page)
- Bore-Gard Locking Strap Information (1 page)
- Brass Adjustable Floor Box Kit - Low Res (4 pages)
- Carflex Installation and Code Information - Low Res (1 page)
- Resi-Gard Flexible Raceway Systems Cost Estimation Sheet - Low Res (2 pages)
- SCMS Future-Proofing in Commercial Applications (2 pages)
- Zip Box Installation Methods - Low Res (2 pages)
- Cementing Joints - Low Res (1 page)
- Chemical Resistance Data - Low Res (2 pages)
- Concrete Encasement Guidelines (1 page)
- Determining the Number of Innerducts Contained in Outerducts (3 pages)
- Drop-In Floor Box (2 pages)
- Duct Proofing and Cable (3 pages)
- E-Loc (1 page)
- Expansion Joints for PVC Rigid Nonmetallic Conduit (6 pages)
- Expansion Joints (6 pages)
- External Load Calculation for Buried Conduit (7 pages)
- Intra-Gard - Low Res (2 pages)
- Ivory Adjustable Floor Box Kit - Low Res (4 pages)
- Multi-Gard Fiberglass Product Description (6 pages)
- Multi-Gard Galvanized Steel Product Description (3 pages)
- Multi-Gard Installation Procedures (7 pages)
- Multi-Gard PVC Product Description (9 pages)
- P&C Duct and Telephone Duct Expansion and Contraction - Low Res (1 page)
- P&C Duct and Telephone Duct Installation Practices - Low Res (1 page)
- P&C Flex and HDPE (4 pages)
- P&C Flex - Low Res (1 page)
- PVC Conduit Painting (1 page)
- PVC Multi-Gard - Low Res (5 pages)
- Rectangular Floor Box, Activation Kit, and Covers (4 pages)
- Round Nonmetallic Floor Box (4 pages)
- Rigid Nonmetallic Conduit Corrision Resistance - Low Res (1 page)
- Rigid Nonmetallic Conduit Properties, Wirefill and Weights - Low Res (1 page)
- Rodent Attack on PVC Conduit or Duct (1 page)