Level – Atec Rohde-Schwarz-SMU200A User Manual
Page 9
Version 08.00, January 2012
Rohde & Schwarz R&S
®
SMU200A Vector Signal Generator
9
Level
standard
–145 dBm to +20 dBm
Setting range
with R&S
®
SMU-B31 or R&S
®
SMU-B36
option
to +30 dBm
standard
f
≤ 3 GHz
+13 dBm (PEP)
2
f > 3 GHz
+11 dBm (PEP)
with R&S
®
SMU-B31 or R&S
®
SMU-B36
option
f
≤ 3 GHz
+19 dBm (PEP)
Maximum level
f > 3 GHz
+17 dBm (PEP)
Resolution
0.01
dB
for levels > –120 dBm,
attenuator mode: auto,
temperature range = +18 °C to +28 °C
1 MHz
≤ f ≤ 3 GHz
< 0.5 dB
Level uncertainty
f > 3 GHz
< 0.9 dB
Additional uncertainty with ALC state: off
(sample & hold)
This function is needed only for some
special applications.
< 0.2 dB
standard, ALC state: on
f
≤ 3 GHz
< 1.6, < 1.4 (typ.)
f > 3 GHz
< 1.85, < 1.6 (typ.)
with R&S
®
SMU-B31 or R&S
®
SMU-B36
option, ALC state: on
attenuator mode: normal
f
≤ 3 GHz
< 1.65, < 1.45 (typ.)
f > 3 GHz
< 1.9, < 1.65 (typ.)
attenuator mode: high power
f
≤ 3 GHz
< 1.7, < 1.5 (typ.)
Output impedance
VSWR in 50
Ω system
f > 3 GHz
< 1.9, < 1.65 (typ.)
after IEC/IEEE bus delimiter,
to < 0.1 dB deviation from final value,
with GUI update stopped,
temperature range = +18 °C to +28 °C
ALC state: on
< 2 ms, 1.5 ms (typ.)
ALC state: off
< 4 ms, 2.5 ms (typ.)
in list mode after trigger impulse to 0.3 dB
deviation from final value
< 450 µs, 300 µs (typ.)
Setting time
1
range switchover with R&S
®
SMU-B31 or
R&S
®
SMU-B36 option
< 10 ms
attenuator mode: fixed, ALC state: on
Uninterrupted level setting
setting range
> 20 dB
maximum permissible RF power in output
frequency range for f > 1 MHz
1 MHz
≤ f ≤ 3 GHz
50 W
f > 3 GHz
10 W
Back-feed (from
≥ 50 Ω source)
maximum permissible DC voltage
50 V
2
PEP = peak envelope power.