Atec Rohde-Schwarz-SMU200A User Manual
Page 27
![background image](/manuals/319544/27/background.png)
Version 08.00, January 2012
Rohde & Schwarz
R&S
®
SMU200A Vector Signal Generator
27
The frequency offset can be used to shift the center frequency of the modulation signal
in the baseband. The restrictions caused by the modulation bandwidth apply.
setting range
−40 MHz to +40 MHz
resolution 0.01
Hz
Frequency offset
frequency uncertainty
< 5 Ч 10
− 10 Ч frequency offset +
reference frequency error
internal
All 0, All 1
PRBS
sequence length
9, 11, 15, 16, 20, 21, 23
pattern
length
1 bit to 64 bit
data lists
R&S
®
SMU-B9 output memory
8 bit to 4 Gbit
R&S
®
SMU-B10 output memory
8 bit to 2 Gbit
R&S
®
SMU-B11 output memory
8 bit to 512 Mbit
nonvolatile memory
hard disk
external
In the case of serial transmission, the symbol strobe marks the LSB of the symbol, and
the maximum symbol rate is limited by the data rate of the interface.
serial
word width
1 bit to 10 bit
bit rate
max. 60 MHz
parallel
word width
1 bit to 10 bit
Data sources
symbol rate
max. 25 MHz
In internal clock mode, a trigger event restarts the clock generation. The clock phase is
then synchronous with the trigger (with a certain timing uncertainty).
In external clock mode, the trigger event is synchronized to the symbol clock.
operating mode
internal, external
modes
auto, retrig, armed auto, armed retrig
setting uncertainty for clock phase related
to trigger in internal clock mode
< 18 ns
external trigger delay
setting range
0 sample to (2
16
– 1) sample
resolution
internal clock mode
0.01 sample
external clock mode
1 sample
setting uncertainty
< 5 ns
external trigger inhibit
setting range
0 sample to (2
26
– 1) sample
resolution 1
sample
external trigger pulse width
> 15 ns
Triggering
external trigger frequency
< 0.02 × sample rate