Atec Rohde-Schwarz-SMU200A User Manual
Page 23
![background image](/manuals/319544/23/background.png)
Version 08.00, January 2012
Rohde & Schwarz
R&S
®
SMU200A Vector Signal Generator
23
Carrier leakage
referenced to full scale
<
−55 dBc, < −65 dBc (typ.)
up to 10 MHz
56 dB (typ.)
Suppression of image sideband for entire
instrument in modulation bandwidth
up to 30 MHz
50 dB (typ.)
wideband noise, with full-scale DC input
20 MHz
≤ f ≤ 200 MHz
–145 dBc (typ.)
200 MHz < f
≤ 1.5 GHz
–148 dBc (typ.)
1.5 GHz < f
≤ 3 GHz
–148 dBc (typ.)
f > 1.5 GHz
–145 dBc (typ.)
ACLR with an ideal input signal, 3GPP test model 1, 64 DPCH
level
≤ 10.5 dBm PEP, ≤ 16.5 dBm PEP with R&S
®
SMU-B31, R&S
®
SMU-B36 options
frequency = 1800 MHz to 2200 MHz
5 MHz offset (baseband gain: 3 dB)
70 dB (typ.)
RF spectral purity
10 MHz offset (baseband gain: 6 dB)
73 dB (typ.)
Digital I/Q inputs
standard
in line with Rohde & Schwarz TVR290,
I/Q data and control signals, data and
interface clock
level LVDS
connector 26-pin
MDR
Interface
data rate
66 MHz to 100 MHz
source
user-defined, digital I/Q in
sample rate
400 Hz to 100 MHz
resolution (user-defined)
0.001 Hz
I/Q sample rate
(max. sample rate depends on interface
data rate)
With source ‘user-defined’, the sample
rate must be entered via the parameter
‘sample rate’, no I/Q data clock being
necessary. With source ‘digital I/Q in’, the
sample rate will be estimated on the basis
of the applied I/Q data clock.
frequency uncertainty (user-defined)
< 5 × 10
−
14
resolution 18
bit
logic format
two’s complement
bandwidth
sample rate = 100 MHz
(no interpolation, user-defined)
40 MHz
I/Q data
sample rate < 100 MHz (interpolation)
0.31 × sample rate
markers 4
Control signals
data valid
valid samples marked in data stream