Version 01.02, September 2013

28

Rohde & Schwarz R&S

®

SMW200A Vector Signal Generator

External trigger input

selectable from USER 1, 2, 3 on front
panel or T/M/C 1, T/M 2, T/M 3 of
respective baseband generator on rear
panel

Connector type

USER 1, 2, 3 on front panel,
T/M/C 1, T/M 2, T/M 3 of respective
baseband generator on rear panel

BNC female

Input level

0 V to 3 V (nom.)

Threshold

settable between 10 mV and 1.9 V

Input impedance

selectable

1 kΩ or 50 Ω (nom.)

Trigger uncertainty

±2.5 ns

External trigger delay

Setting range

0 sample to (2

16

– 1) sample

Setting resolution

5 ns

External trigger inhibit

Setting range

0 sample to (2

26

– 1) sample

Setting resolution

1 sample

External trigger pulse width

> 7.5 ns

Marker signals
Number of marker signals

3

Operating modes

control list, pulse, pattern, ratio

Marker outputs

selectable from USER 1, 2, 3 on front
panel or T/M/C 1, T/M 2, T/M 3 of
respective baseband generator on rear
panel

Connector type

USER 1, 2, 3 on front panel,
T/M/C 1, T/M 2, T/M 3 of respective
baseband generator on rear panel

BNC female

Level

LVTTL

Marker delay

Setting range

0 sample to (2

24

– 1) sample

without recalculation

0 sample to 2000 sample

Setting resolution