Adjust level function

automatically determines peak level and crest factor of input signal

I/Q swap

I and Q signals swapped

on/off

Interface

Standard

in line with R&S

®

Digital I/Q Interface

PAD-R

10

,

I/Q data and control signals, data and
interface clock

Level

LVDS

Connector

26-pin

MDR

I/Q sample rate

With source ‘user-defined’, the sample rate must be entered via the parameter ‘sample
rate’, no I/Q data clock being necessary. With source ‘digital I/Q in’, the sample rate will
be estimated on the basis of the applied I/Q data clock.

Source

user-defined, digital I/Q in

Sample rate

max. sample rate depending on connected
transmitting device

400 Hz to 200 MHz

Resolution (user-defined)

0.001 Hz

Frequency uncertainty (user-
defined)

< (5 × 10

14

+ relative deviation of

reference frequency) × sample rate (nom.)

I/Q data

Resolution

18

bit

Logic format

two’s complement

Bandwidth

sample rate = 200 MHz (no interpolation,
user-defined)

160 MHz

sample rate < 200 MHz (interpolation)

0.8 × sample rate

Control signals

markers

3

I/Q baseband generator (R&S

®

SMW-B10 option) – arbitrary waveform mode

One or two R&S

®

SMW-B10 can be installed. Their I/Q signals can be assigned a frequency offset and/or be added in the digital

domain with settable level ratio.

Waveform length

1 sample to 64 Msample in one-sample
steps

with R&S

®

SMW-K511 option (memory

extension)

1 sample to 512 Msample in one-sample
steps

with R&S

®

SMW-K512 option (memory

extension)

1 sample to 1 Gsample in one-sample
steps

Nonvolatile memory

hard disk

Sample resolution

equivalent to D/A converter

16 bit

Sample rate

400 Hz to 150 MHz

with R&S

®

SMW-K522 option

400 Hz to 200 MHz

Sample frequency error

internal clock

< (5 × 10

14

+ relative deviation of

reference frequency) × sample rate (nom.)

Sample clock source

internal, external

Bandwidth (RF)

using the maximum sample rate,
rolloff to –0.1 dB

120 MHz

using a reduced sample rate,
rolloff to –0.1 dB
(The waveform is automatically
interpolated to the internal sample rate of
150 MHz.)

0.8 × sample rate

Bandwidth (RF) with R&S

®

SMW-K522

option

using the maximum sample rate,
rolloff to –0.1 dB

160 MHz

using a reduced sample rate,
rolloff to –0.1 dB
(The waveform is automatically
interpolated to the internal sample rate of
200 MHz.)

0.8 × sample rate

10

R&S

®

Digital I/Q Interface PAD-R is a Rohde & Schwarz internal company standard for the transmission of digital I/Q data. It is supported by a wide

range of signal generators, signal analyzers and radiocommunications testers.