beautypg.com

Simultaneous modulation, Phase coherence (r&s, Smw-b90 option) – Atec RohdeSchwarz-SMW200A User Manual

Page 13

background image

Version 01.02, September 2013

Rohde & Schwarz R&S

®

SMW200A Vector Signal Generator

13

Phase coherence (R&S

®

SMW-B90 option)

The R&S

®

SMW-K90 option provides phase-coherent RF outputs for the two RF paths or two or more instruments. For frequencies

above 200 MHz, the LO output and input frequency are set to the output frequency.

LO coupling modes

This mode corresponds to internal
LO operation in path A and path B.

A, B internal

This mode corresponds to internal
LO operation in path A, and LO of path B
is coupled to path A.

A internal,
A → B coupled

This mode corresponds to external
LO operation at the LO IN connector in
path A and internal LO operation in path B.

A external,
B internal

This mode corresponds to external
LO operation at the REF/LO IN connector
in path A and path B.

A external,
A → B coupled

REF/LO OUT states

The active LO signal of path B can be
routed to the LO OUT connector (in order
to couple two or more instruments).

on/off

Input of phase coherence signal
Connector type

LO IN on rear panel

SMA female

Input impedance

50 Ω (nom.)

Input level range of external LO signal

7 dBm to 13 dBm

Frequency range of external LO signal

for RF setting 200 MHz < f ≤ 6 GHz

200 MHz to 6 GHz

Output of phase coherence signal
Connector type

LO OUT on rear panel

SMA female

Output impedance

50 Ω (nom.)

Output level range of internal LO signal

7 dBm to 13 dBm

Frequency range of internal LO signal

for RF setting 200 MHz < f ≤ 6 GHz

200 MHz to 6 GHz

Simultaneous modulation

In the same RF path.

Amplitude

modulation

Frequency
modulation

Phase modulation

Pulse modulation I/Q

modulation

Amplitude
modulation

○ –

Frequency
modulation

● – ●

Phase modulation

● – ●

Pulse modulation

I/Q modulation

● = compatible, – = incompatible,
○ = compatible with limitations

For simultaneous I/Q and frequency modulation, or simultaneous I/Q and phase modulation, the instrument must be equipped with a
two-path signal routing and baseband main module (R&S

®

SMW-B13T option).