Dynamic range specifications – Atec Agilent-N9010A User Manual
Page 9
9
Dynamic Range Specifications
1 dB gain compression (two-tone)
Total power at mixer input
RF/MW
(Option 503, 507, 513, 526)
20 MHz to 26.5 GHz
+9 dBm nominal
Total power at mixer input
Millimeter-wave
(Option 532, 544)
20 MHz to 26.5 GHz
+6 dBm nominal
26.5 to 44 GHz
0 dBm nominal
Total power at preamp input
Preamp on
10 MHz to 3.6 GHz
3.6 to 26.5 GHz
Tone spacing: 100 kHz to 20 MHz
Tone spacing: > 70 MHz
> 26.5 GHz
–14 dBm nominal
–28 dBm nominal
–20 dBm nominal
–30 dBm nominal
Displayed average noise level (DANL)
(Input terminated, sample or average detector, averaging type = Log, 0 dB input attenuation, IF Gain = High, 20 to 30 °C)
Specification
Typical
RF/MW
(Option 503, 507, 513, 526)
1 to 10 MHz
–147 dBm
–149 dBm
10 MHz to 2.1 GHz
–148 dBm
–150 dBm
2.1 to 3.6 GHz
–147 dBm
–149 dBm
3.6 to 7.0 GHz
–147 dBm
–149 dBm
7.0 to 13.6 GHz
–143 dBm
–147 dBm
13.6 to 17.1 GHz
–137 dBm
–142 dBm
17.1 to 22 GHz
–137 dBm
–142 dBm
22 to 26.5 GHz
–134 dBm
–140 dBm
Preamp on, RF/MW
(Option 503, 507, 513, 526)
10 MHz to 2.1 GHz
–161 dBm
–163 dBm
2.1 to 3.6 GHz
–160 dBm
–162 dBm
3.6 to 7.0 GHz
–160 dBm
–162 dBm
7.0 to 13.6 GHz
– 160 dBm
–163 dBm
13.5 to 17.1 GHz
–157 dBm
–155 dBm
17.0 to 20.0 GHz
–155 dBm
–159 dBm
20.0 to 26.5 GHz
–150 dBm
–156 dBm
Millimeter-wave
(Option 532, 544)
9 kHz to 1 MHz
–
–130 dBm
1 MHz to 1.2 GHz
–152 dBm
–155 dBm
1.2 to 2.1 GHz
–151 dBm
–154 dBm
2.1 to 3.6 GHz
–149 dBm
–152 dBm
3.5 to 4.2 GHz
–144 dBm
–147 dBm
4.2 to 8.4 GHz
–145 dBm
–150 dBm
8.3 to 13.6 GHz
–147 dBm
–150 dBm
13.5 to 20 GHz
–145 dBm
–148 dBm
20 to 26.5 GHz
–142 dBm
–145 dBm
26.4 to 34 GHz
–140 dBm
–144 dBm
34.4 to 44 GHz
–135 dBm
–140 dBm
1. N is the LO multiplication factor.