beautypg.com

Mounting the switcher, Tabletop use, Ul rack-mounting guidelines – Extron Electronics MVX 44_48_84_88 Series User Guide User Manual

Page 69: Mounting instructions, Optional accessories cables, Detailed mounting instructions, Can be found in the “refer, Mounted on a rack shelf

background image

Mounting the Switcher

The MVX switchers are housed in a rack-mountable, 1U high, metal enclosures. Included
mounting hardware lets you install the switcher in any standard 19-inch rack or into furniture.

Tabletop Use

For tabletop use, affix one of the supplied self-adhesive rubber feet to each corner of the
bottom of the switcher.

UL Rack-Mounting Guidelines

The following Underwriters Laboratories (UL) requirements pertain to the installation of the
matrix switcher into a wall or furniture.

1.

Elevated operating ambient temperature — If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient. Therefore, consider installing the equipment in an environment
compatible with the maximum ambient temperature (Tma = +122 °F, +50 °C) specified
by Extron.

2.

Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.

3.

Mechanical loading — Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.

4.

Circuit overloading — Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.

5.

Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (such as use of power strips).

Mounting Instructions

If desired, mount the switcher in a rack or through furniture in accordance with the
directions included with the mounting kit.

MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Reference Information

63