beautypg.com

Switcher error responses, Using the command and response table – Extron Electronics MVX 44_48_84_88 Series User Guide User Manual

Page 44

background image

Mut

n

1

]

The switcher initiates the Mut message when an IR 501 remote control output video and
audio mute command has occurred. “n” is the output number and “1” indicates the mute
function is turned on (the output is muted).
Zpz

]

The switcher initiates the Zpz message when an IR 501 remote control output unmute
command has occurred. All video and audio outputs are unmuted.

Switcher Error Responses

When the switcher receives an SIS command and determines that it is valid, it performs the
command and sends a response to the host device. If the switcher is unable to perform
the command because the command is invalid or contains invalid parameters, the switcher
returns an error response to the host. The error response codes are:
E01 — Invalid input channel number (out of range)

E10 — Invalid command

E11 — Invalid preset number (out of range)

E12 — Invalid output number (out of range)

E13 — Invalid value (out of range)

E14 — Invalid command for this configuration

Using the Command and Response Table

The command and response table begins on

page 39

. Symbols used in the table represent

variables in the command and response fields. Command and response examples are shown
throughout the table. The ASCII to HEX conversion table below is for use with the command
and response table.

ASCII to Hex Conversion Table

Space

NOTE: With the exception of the audio input gain and attenuation commands, the SIS

commands are not case sensitive.

MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Remote Operation