Command/Response Table for SIS Commands (continued)

Command Function

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional description

RGB mute commands

RGB mute

X@

*1B

Vmt

X@

*1

]

Mute output

X@

RGB (video off).

RGB unmute

X@

*0B

Vmt

X@

*0

]

Unmute output

X@

RGB (video on).

Read RGB mute

X@

B

X#]

1 = mute on, 0 = mute off.

Global RGB mute

1*B

Vmt1

]

Mute all RGB outputs.

Global RGB unmute

0*B

Vmt0

]

Unmute all RGB outputs.

IR 501 mute command responses

NOTE

:

An IR 501 user can mute video, audio, or both with a string of IR commands that cannot be duplicated by a computer or control

system sending SIS commands. The switcher sends the following responses shown in the entries below.

IR 501 RGB and audio mute

{none}

Mut

X@

*1

]

The RGB and audio from output

X@

are

muted.

IR 501 RGB mute

{none}

Vmt

X@

*1

]

The RGB from

X@

output is muted.

IR 501 RGB and audio unmute

{none}

Zpz

]

The RGB and audio from output

X@

are

unmuted.

Audio input gain and attenuation

NOTE

:

The set gain (G) and set attenuation (g) commands are case sensitive.

Set audio input gain to +dB value

X$

*

X%

G

In

X$

•Aud

X^]

Example:

1*2G

In1•Aud+02

]

Set input 1 audio gain to +2 dB.

Set audio input attenuation to -dB
value

X$

*

X&

g

In

X$

•Aud

X^]

Increment gain

X$

+G

In

X$

•Aud

X^]

Increase gain by 1 dB.

Example:

5+G

In5•Aud+03

]

Increase audio input 5 level from +2 dB
to +3 dB.

Decrement gain

X$

-G

In

X$

•Aud

X^]

Decrease gain by 1 dB.

Example:

7-G

In7•Aud-09

]

Decrease audio input 7 level from -8 dB
to -9 dB.

Read input gain

X$

G

X^]

Example:

3G

-06

]

Audio input 3 level is at -6 dB.

Audio output level

Set audio output to the consumer
level (-10 dBV)

X@

*0*40#

Out

X@

•Lvl0

]

Set output

X@

level to consumer (-10

dBV).

Set audio output to the professional
level (+4 dBu)

X@

*1*40#

Out

X@

•Lvl1

]

Set output

X@

level to pro (+4 dBu)

(default).

Read output level

X@

+40#

X*]

Example:

3*40#

1

]

Output 3 audio level is pro (+4 dBu).

Audio mute commands

Audio mute

X@

*1Z

Amt

X@

*1

]

Mute output

X@

audio (audio off).

Audio unmute

X@

*0Z

Amt

X@

*0

]

Unmute output

X@

audio (audio on).

Read audio mute

X@

Z

X#]

1 = mute on, 0 = mute off.

Global audio mute

1*Z

Amt1

]

Mute all audio outputs.

Global audio unmute

0*Z

Amt0

]

Unmute all audio outputs.

NOTE:

X@

= Output number

1 through 4 (MVX 44, MVX 84) or 1 through 8 (MVX 48, MVX 88)

X#

= Mute status

1 = on

0 = off

X$

= Input number

1 through 4 (MVX 44, MVX 48) or 1 through 8 (MVX 84, MVX 88)

X%

= Input audio gain

0 through 10 (1 dB per step)

X^

= Numeric dB value

–18 to +10 (29 steps [dB] of audio attenuation and gain)

X&

= Input audio attenuation

1 through 18 (1 dB per step)

X*

= Output gain

0 = consumer level (–10 dBV) 1 = pro level (+4 dBu)

MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Remote Operation