beautypg.com

Resetting the system to factory defaults, Memory, Resetting the system to factory defaults memory – Extron Electronics MVX 44_48_84_88 Series User Guide User Manual

Page 36

background image

Resetting the System to Factory Defaults

To reset a switcher to the factory default settings, press and hold the I/O button on the front
panel while applying AC power (see

figure 17

). Continue to hold the I/O button until all

LEDs light and then release the I/O button. The power up sequence completes (all LEDs turn
off then turn on and off from left to right, the Video and Audio LEDs turn on, and all other
LEDs remain off). System reset does the following:

Clears all ties and presets.

Clears all video and audio mutes.

Sets all input audio gain levels to their default (0 dB) values.

Returns the output audio level to the professional (+4 dBu) level.

I / O

I/O

AUD

VID

I/O

AUD

VID

Press and

hold the I/O button while

you apply power to the switcher.

Power

I/O

AUD

AUDIO SETUP

PRESET

VID

+dB

-dB

1

1

The switcher lights

all of the LEDs.

The switcher continues the power up process.

Release the I/O button.

Figure 17.

System Reset to Factory Defaults

Memory

The current configuration, all presets, and all input audio levels are saved in non-volatile
memory within 5 seconds of a change or exiting Audio Setup mode. When power is applied,
the last current configuration is retrieved. The previous presets remain intact.

NOTE: Wait at least 5 seconds after changing any configuration, saving a preset, or

exiting Audio Setup mode. Before 5 seconds have elapsed, changes that you
have made may not have been saved.

MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Operation

30