background image

Installation

System 182 XT-4

3 - 38

ba76027e01

02/2012

Fig. 3-27 Line power connection.

Note
The complete assignment of the terminal strip is shown in section 3.14.

Warning

No free wires must be allowed to project into the enclosure.
Otherwise, there is a danger that areas safe to contact could come
into contact with dangerous voltages. Always cut off any wires
that are not in use as closely as possible to the cable gland.

9

Connect phases L and N to the terminal strip. Make sure that
the cable assignment agrees with the specification on the
terminal label under the terminal strip.

10

Tighten the coupling ring (pos. 3 in Fig. 3-26).

11

Close the enclosure of the DIQ/S 182 XT-4-PR.

N

L

Terminal
labeling:

X17

X16

100...

240V AC

MAINS

L1

N