Car2512te front-end, Preliminary data sheet, Input: 90v – GE Industrial Solutions CAR2512TE Front-End User Manual
Page 3: Output: 12 v, Standby @ 15w, General specifications, Feature specifications

GE
Preliminary Data Sheet
CAR2512TE Front-End
Input: 90V
AC
to 264V
AC
; Output: 12 V
DC
@ 2500W; 3.3/5V
DC
standby @ 15W
February 7, 2014
©2013 General Electric Company. All rights reserved.
Page 3
12V
dc
MAIN OUTPUT (continued)
Parameter
Symbol
Min
Typ
Max
Unit
Remote ON/OFF delay time
40
ms
Turn-ON rise time (10 – 90% of V
OUT
)
50
ms
Transient response 50% step [10%-60%, 50% - 100%]
(dI/dt – 1A/µs, recovery 300µs)
V
OUT
-5 +5
%V
OUT
Programmable range (hardware & software)
10.8
13.2
V
DC
Overvoltage protection, latched
(recovery by cycling OFF/ON via hardware or software)
13.8 14.8 15.8 V
DC
Output current V
IN
= HL
V
IN
= LL
I
OUT
0
208
100
A
DC
Current limit, Hiccup (programmable level) HL / LL
105/105
130/140
% of FL
Active current share (I
OUT
≥ 20% of FL)
-5
+5
% of FL
STANDBY OUTPUT
Parameter
Symbol
Min
Typ
Max
3.3 / 5 / 12
Unit
Set point
V
OUT
3.3 / 5.0 / 12
V
DC
Factory set point accuracy (25C, 50% load)
-3 +3
%
Overall regulation (line, load, temperature, aging)
-5
+5
%
Ripple and noise
50 / 50 / 120
mV
P-P
Output power
I
OUT
0 15
W
DC
Overload protection -
Overvoltage protection
110
%
Isolation Output/Frame
100
V
DC
General Specifications
Parameter
Min
Typ
Max
Units
Notes
Reliability
400,000
Hrs
Full load, 25C ; MTBF per SR232 Reliability
protection for electronic equipment, method I,
case III,
Service Life
10
Yrs
Full load, excluding fans
Weight
5.2
/2.36
Lbs/kg
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter
Symbol
Min
Typ
Max
Unit
Remote ON/OFF (pulled up internally within the module to V
stdby
)
Logic High (Module ON)
2.5 5 V
DC
Logic Low (Module OFF, internal resistance 9kΩ) I
IL
1 mA
V
IL
0
0.8 V
DC