Initiating a Hardware Reset on the Modbus Gateway

To initiate a Hardware Reset on the Modbus gateway, press the Mode/Reset switch
for less than two seconds, and release it. The LED indicators respond as follows:

1. The Ready LED blinks three times per second while the button is being pressed.

2. The Modbus gateway is in Reset Mode when Port 1 LED is On and the Ready LED is

Off.

3. The LEDs go back to their normal states when the device resumes normal operation.

Reloading Factory Defaults

To reload Factory Defaults, press and hold the Mode/Reset switch for more than 10
seconds. The LED indicators respond as follows:

1. The Ready LED blinks three times per second while the button is being pressed.

2. The Modbus gateway reloads all factory default configuration parameters.

3. The LEDs go back to their normal states when the device resumes normal operation.