beautypg.com

B&B Electronics MESR424T_D-MT_D-SC - Manual User Manual

Page 38

background image

3. Setup and Connections

38

b. Click on Internet Protocol (TCP/IP) and click the Properties button. Change

the parameters to the following:

IP Address = 169.254.102.1

Subnet Mask = 255.255.0.0

Default Gateway = 169.254.102.100

c. Use the Vlinx Modbus Manager Software to search for, discover, and

configure the Modbus Gateway.

2. Method 2: Change the Modbus Gateway’s network settings to match your PC using

Console Mode