(Revised 8/4/2009)

22

Aging Menu

When enabled, the Aging Time for dynamically learned addresses can be set from 10 to 300 seconds. The
default is 300 seconds, except it is 20 seconds for 508FX2 and 526FX2. Cycling power clears the learned
addresses.

Note:

The configuration console is only available with –A models.

On –N and basic (no dash) units, aging is enabled and uses the defaults above without the option for
reconfiguration.

Command

Description

Comment

info

Displays the current Aging
settings.

Default is 300 seconds, except it is
20 seconds for 508FX2 and
526FX.

disable (or
enable)

Enable Disable Aging

Choice is opposite of current
state

config

Choose aging time.

10 to 300 seconds

Example of the Aging config screen:

CLI\SYSTEM\AGING>config

Configure Aging Time.

The aging process is Enabled.

Aging time is now 20 seconds.

Enter an aging timeout ( 10 to 300 seconds),
or to exit> 15

The aging process is Enabled.

Aging time is now 15 seconds.

CLI\SYSTEM\AGING>


Example of the Aging info screen:

CLI\SYSTEM\AGING>info

The aging process is Enabled.

Aging time is now 15 seconds.


CLI\SYSTEM\AGING>