beautypg.com

Rainbow Electronics DS2188 User Manual

Page 8

background image

DS2188

021997 8/11

AC ELECTRICAL CHARACTERISTICS

(0

°

C to 70

°

C; V

DD

=5V

±

10%)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

RCLK Period

t

P

–200

+200

ppm

1

RCLK Pulse Width

t

WH

,t

WL

100

ns

RCLK Rise and Fall Times

t

R

, t

F

50

ns

RPOS, RNEG Setup to RCLK

t

SD

50

ns

RPOS, RNEG Hold from RCLK

t

HD

50

ns

Propagation Delay from RRCLK
to RRPOS, RRNEG Valid

t

PD

50

ns

Propagation Delay from XTAL
OUT to RRCLK

t

PDC

50

ns

2

RST Pulse Width

t

RST

1

µ

s

NOTES:

1. The average period of RCLK must be within

±

200 ppm of the fundamental frequency of the crystal divided by four.

2. Only valid when the incoming jitter is less than 120UIpp (BDS=0) or 28UIpp (BDS=1).