3 active mode – Rainbow Electronics ATA5746 User Manual

Page 21

background image

21

4596A–RKE–05/06

ATA5745/ATA5746 [Preliminary]

Figure 5-2.

Standby Mode (CLK_OUT_CTRL0 or CLK_OUT_CTRL1 = 1)

5.3

Active Mode

The Active mode is enabled by setting the level on pin RX to high. In Active mode, the RX signal
path is enabled and if a valid signal is present it will be transferred to the connected
microcontroller.

During T

Startup_PLL

the PLL is enabled and starts up. If the PLL is locked, the signal processing

circuit starts up (T

Startup_Sig_Proc

). After the start-up time, all circuits are in stable condition and

ready to receive. The duration of the start-up sequence depends on the selected bit rate range.

Figure 5-3.

Active Mode

CLK_OUT

ENABLE

Standby Mode

t

XTO_Startup

Table 5-3.

Active Mode

RX

ENABLE

Function

1

1

Active mode

DATA_OUT valid

t

Startup_PLL

t

Startup_Sig_Proc

I

Startup_PLL

I

Active

I

Active

I

Standby

Startup

CLK_OUT

RX

DATA_OUT

ENABLE

Standby Mode

Active Mode