DS1842A

76V, APD, Bias Output Stage with

Current Monitoring

_______________________________________________________________________________________

5

Pin Description

PIN

NAME

FUNCTION

1

MIR1

Current Mirror Monitor Output, 10:1 Ratio

2

MIR2

Current Mirror Monitor Output, 5:1 Ratio

3 GND

Ground Connection for Device. Connect directly to ground plane. Connect GND to PGND at a
single point. See the Layout Considerations section for more information.

4

FBOUT

Feedback Output. Resistor-divider output.

5

CLAMP

Clamp Input. Disables the current mirror output (MIROUT).

6 GATE

FET

Gate

Connection

7 PGND

Source of Switch FET. Also connect to boost converter’s input and output capacitors. Connect
PGND to GND at a single point. See the Layout Considerations section for more information.

8

LX

FET Drain Connection. Connect to switching inductor.

9, 10, 11

N.C.

No Connection

12

FBIN

Feedback Input. Resistor-divider input.

13

MIRIN

Current Mirror Input

14

MIROUT

Current Mirror Output. Connect to APD bias pin.

EP

Exposed Pad. Connect directly to the same ground plane as GND.

Block Diagram

TDFN

TOP VIEW

2

4

5

13

11

10

MIRIN

N.C.

N.C.

MIR2

FBOUT

CLAMP

1

14

MIROUT

MIR1

3

12

FBIN

GND

6

9

N.C.

GATE

7

8

LX

PGND

DS1842A

*EP

*EXPOSED PAD.

+

DS1842A

LX

GATE

PGND

MIRIN

MIR1

CLAMP

MIROUT

CURRENT MIRROR

CURRENT

LIMIT

FBIN

MIR2

THERMAL

SHUTDOWN

FBOUT

R

1

R

2

GND

EP

Pin Configuration

Detailed Description

The DS1842A contains discrete high-voltage compo-
nents required to create an APD bias voltage and to
monitor the APD bias current. The device’s mirror out-
puts are a current that is a precise ratio of the output
current across a large dynamic range. The mirror
response time is fast enough to comply with GPON Rx
burst-mode monitoring requirements. The device has a
built-in current-limiting feature to protect APDs. The

APD current can also be shut down by CLAMP or ther-
mal shutdown. The internal FET and resistor-divider are
used in conjunction with a DC-DC boost controller to
precisely create the APD bias voltage.

Current Mirror

The DS1842A has two current mirror outputs. One is a
10:1 mirror connected at MIR1, and the other is a 5:1
mirror connected to MIR2.