beautypg.com

Out4 (ldo4) electrical characteristics, Out5 (ldo5) electrical characteristics – Rainbow Electronics MAX8982X User Manual

Page 14

background image

Power-Management ICs for

ICERA E400/E450 Platform

MAX8982A/MAX8982X

14

OUT4 (LDO4) ELECTRICAL CHARACTERISTICS

(MAX8982A/MAX8982X: V

IN3

= V

BUCK2

= 1.8V, C

IN3

= 2.2FF, C

REFBP

= 0.1FF, C

OUT4

= 2.2FF, T

A

= -40NC to +85NC, unless other-

wise noted. Typical values are at T

A

= +25NC.) (Note 3)

OUT5 (LDO5) ELECTRICAL CHARACTERISTICS

(MAX8982A: V

DDB

= +3.2V and C

VDD_

= 10FF, MAX8982X: V

DDB

= +3.3V and C

VDD_

= 20FF, C

REFBP

= 0.1FF, C

OUT5

= 1FF,

T

A

= -40NC to +85NC, unless otherwise noted. Typical values are at T

A

= +25NC.) (Note 3)

PARAMETER

CONDITION

MIN

TYP

MAX

UNITS

Default Output Voltage

I

LOAD

= 10mA

0.873

0.9

0.927

V

Maximum Output Current

50

mA

Current Limit (Note 4)

V

OUT4

= 90% of its regulation

55

120

220

mA

Load Regulation

50FA < I

LOAD

< 10mA

25

mV

Power-Supply Rejection
D

V

OUT

/DV

IN

f = 10Hz to 10kHz, I

LOAD

= 10mA

60

dB

Output Noise Voltage

100Hz to 100kHz, I

LOAD

= 10mA

45

F

V

RMS

Programmable Output Voltage

I

LOAD

= 10mA

0.80

V

0.90
1.00
1.10
1.20

Startup Time from Shutdown
(Note 4)

I

LOAD

= 50mA

100

F

s

Startup Transient Overshoot
(Note 4)

I

LOAD

= 50mA

50

mV

Shutdown Output Impedance
(Active Discharge Resistance)

I

2

C programmable, default off

100

I

PARAMETER

CONDITION

MIN

TYP

MAX

UNITS

Default Output Voltage

I

LOAD

= 50mA

2.91

3.00

3.09

V

Maximum Output Current

150

mA

Current Limit (Note 4)

V

OUT5

= 90% of its regulation

165

360

650

mA

Dropout Voltage (Note 4)

I

LOAD

= 100mA, T

A

= +85NC

150

300

mV

Line Regulation

3.2V P V

DDB

P 3.65V, I

LOAD

= 100mA

2.4

mV

Load Regulation

50FA < I

LOAD

< 150mA, V

OUT

= 2.8V

25

mV

Power-Supply Rejection
D

V

OUT

/DV

IN

f = 10Hz to 10kHz, I

LOAD

= 30mA

60

dB

Output Noise Voltage

100Hz to 100kHz, I

LOAD

= 30mA

45

F

V

RMS

Programmable Output Voltage

I

LOAD

= 50mA, V

DDB

= 3.4V for V

OUT

= 3.2V

2.80

V

2.90
3.00
3.20

Startup Time from Shutdown
(Note 4)

I

LOAD

= 150mA

100

F

s

Startup Transient Overshoot
(Note 4)

I

LOAD

= 150mA

50

mV

Shutdown Output Impedance
(Active Discharge Resistance)

I

2

C programmable, default off

100

I