The meaning of the indicators is as follows:

OK: The stream is operating normally. If it is an encoder, it means that it is operating

normally; if it is an output, it means that it is either transmitting or ready to transmit.

Warn: The stream is configured but disabled. Simply enabling the stream may clear

this situation.

Error: The stream is configured but has detected a problem. If it is an encoder, it is

not running. If this is an output, it normally means that the output is either unable to send
(e.g., an IP output configured for unicast but unable to find the destination MAC address)
or dropping packets (e.g., an oversubscribed ASI or IP output in manual rate mode). ASI
Outputs with Automatic Rate will be in this state if they do not have data to transmit.

A sample of the Connection Statistics Tab is depicted below.

MPTS Configuration Tab

If two encoder channels are installed in the 9223-SA, the MPTS Configuration Tab is available.
This tab contains information specific to muxing the two encoders into one Multi-Program
Transport Stream (MPTS).