5. Assembly

PNEG-720-G2 12" and 16" Series II Sweep

49

Figure 5AG

R. Assemble the cord plugs to the other end of each cord. The 14 AWG/4 wire cord requires the

(GC03670) plug. The 10 AWG/4 and 8 AWG/4 wire cord requires the (GC03668) plug.
The 14 AWG/3 wire cord requires the (GC03672) plug.

S. Mount the control panel outside the bin near the door.

CAUTION

The plugs are different for each cord and MUST be assembled correctly. This
prevents cords from being plugged into the control panel incorrectly.

WARNING

The control panel MUST be mounted OUTSIDE the bin, near the door. The foot
switch has to be plugged into the control panel and depressed before the sweep
is operational. It has a 10' cord so the sweep can only be monitored from
OUTSIDE the bin.