beautypg.com

It coupling, See figure 5ab – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-720-G2 User Manual

Page 46

background image

5. Assembly

46

PNEG-720-G2 12" and 16" Series II Sweep

4. Thread a steel ring into the 3/4" flex conduit.

(See Figure 5AB.)

5. Thread the 3/4" flex conduit coupling cap onto the 3/4" flex conduit coupling body.

(See Figure 5AB.)

Figure 5AB

D. Attach the 3/4" x 12" liquid-tight flex conduit to the other end of the rigid conduit using one 3/4"

conduit coupling and one 3/4" liquid-tight flex conduit coupling.

(See Figure 5AC.)

E. Connect the two (2) junction boxes together using the 1" x 4-3/4" conduit nipple.

(See Figure 5AC.)

F. Connect the 3/4" x 12" liquid-tight flex conduit to the left junction box using one 3/4" liquid-tight flex

conduit coupling and one 1" to 3/4" reducer bushing.

(See Figure 5AC.)

G. Attach the 3/4" x 40" liquid-tight flex conduit to the right junction box using one 3/4" liquid-tight flex

conduit coupling and one 1" to 3/4" reducer bushing.

(See Figure 5AC.)

Figure 5AC