Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-720-G2 User Manual
Page 48
5. Assembly
48
PNEG-720-G2 12" and 16" Series II Sweep
L. Attach the 3/4" rigid conduit assembly to the sweep using the 5/16"-18 x 3/4" studs welded to the
sweep using 1" conduit clamps, lock washers and hex nuts.
M. Run the 14 AWG stranded wires into the drive motor and fasten the 3/4" x 48" liquid-tight flex conduit
to the motor using one 3/4" liquid-tight flex conduit coupling. Some motors may require a reducer
bushing not supplied with the sweep. Connect the leads as required.
Figure 5AF
N. Run the 10 AWG stranded wires into the auger motor and fasten the 3/4" x 40" liquid-tight flex conduit
to the motor using one 3/4" liquid-tight flex conduit coupling. Some motors may require a reducer
bushing not supplied with the sweep. Connect the leads as required.
NOTE: If you are using the pivot kit, skip to
and refer to “
”.
O. Tractor Drive: Slide a 5/8" to 3/4" cord connector six inches (6") onto one end of the
14 AWG/4 wire cords and fasten it to the junction box using one 1" to 3/4" reducer bushings. Connect
the leads as required.
Sweep Drive all 12" and 16" under 105 Model: Slide a 5/8" to 3/4" cord connector six inches (6")
onto one end of the 10 AWG/4 wire cords and fasten it to the junction box using one 1" to 3/4" reducer
bushings. Connect the leads as required.
Sweep Drive all 16" 105 Model and over: Slide a 5/8" to 3/4" cord connector six inches (6")
onto one end of the 8 AWG/4 wire cords and fasten it to the junction box using one 1" to
3/4" reducer bushings. Connect the leads as required.
P. Slide a 1/2" to 5/8" cord connector six inches (6") onto the end of the 14 AWG/3 wire cord
and fasten it to the junction box using one 1" to 3/4" reducer bushings. Connect the leads
as required.
Q. Use the plugs provided with the junction boxes to close the holes not being used.