beautypg.com

Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-720-G2 User Manual

Page 47

background image

5. Assembly

PNEG-720-G2 12" and 16" Series II Sweep

47

H. Feed each of the six (6) 14 AWG stranded wires through the 3/4" rigid conduit assembly and cut

them off, leaving six inches (6") at both the left junction box and drive motor.

I. Feed each of the six (6) 10 AWG stranded wires cord through the 3/4" x 40" liquid tight flex conduit

and cut four (4) of them off, leaving six inches (6") at both the right junction box and auger motor. Cut
the 10 AWG blue and yellow wires longer so they can be connected to the 14 AWG blue and yellow
wires in the left junction box.

J. Place the 3/4" rigid conduit assembly onto the back frame of the sweep between the connecting angle

and connecting flange.

(See Figure 5AD.)

Figure 5AD

K. Fasten the junction boxes to the mounting plate using two (2) 3/8"-16 x 1-3/8" U-bolts, four (4) lock

washers and hex nuts.

(See Figure 5AE.)

Figure 5AE