Taper-lock bushings, General product information – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-720-G2 User Manual
Page 22
4. General Product Information
22
PNEG-720-G2 12" and 16" Series II Sweep
Taper-Lock Bushings
Figure 4A Number 1008 to 3030 Bushing
To Install
1. Clean shaft, bore and outside of bushing and hub bore of all oil, paint and dirt. File
away burrs.
2. Insert bushing in hub. Match the hole pattern, not threaded holes (each complete hole will be
threaded on one side only).
3. Lightly oil set screws and thread into the half-threaded holes indicated as in
.
4. Position the assembly onto the shaft allowing for the small axial movement which will occur during
the tightening procedure.
5. Alternately torque set screws to recommended torque setting listed in the
.
6. To increase the gripping force, hammer the face of the bushing using a drift or sleeve. (Do not hit the
bushing directly with the hammer.)
7. Re-torque the screws after hammering.
8. Recheck the screw torques after the initial run-in and periodically thereafter. Repeat
,
and
if loose.
Recommended Installation Wrench Torque
To Remove
1. Remove all screws.
2. Insert screws in hole or holes indicated on
. Loosen the bushing by tightening the screw(s).
Bushing No.
lb-in
Bushing No.
lb-in
1008, 1108
55
3535
1000
1210, 1215, 1310
175
4040
1700
1610, 1615
175
4545
2450
2012
280
5050
3100
2517, 2525
430
6050, 7060, 8065
7820
3020, 3030
800
CAUTION
Wedging forces in the bushing saw slot, such as that exerted by a narrow edged
regular screw driver, may damage or break the bushing. This damage would not
be covered under the GSI warranty.
Do not lubricate the bushing taper, bushing bore, hub taper or the shaft. Doing so
could result in breakage of the product.
Do not use worn hex key wrenches. Doing so may result in a loose assembly or
may damage the screws.
CAUTION
Insert Set Screws to Install
Insert Set Screw to Remove