C-series dryer quick reference guide – Grain Systems PNEG-573 User Manual
Page 84

84
C-SERIES DRYER QUICK REFERENCE GUIDE
C-SERIES DRYER QUICK REFERENCE GUIDE
C-SERIES DRYER QUICK REFERENCE GUIDE
C-SERIES DRYER QUICK REFERENCE GUIDE
C-SERIES DRYER QUICK REFERENCE GUIDE
ELECTRONIC MONITORING CONTROL SYSTEM
ELECTRONIC MONITORING CONTROL SYSTEM
ELECTRONIC MONITORING CONTROL SYSTEM
ELECTRONIC MONITORING CONTROL SYSTEM
ELECTRONIC MONITORING CONTROL SYSTEM
Change the marquee on the LCD
display:
•
Press and hold the MODIFY but-
ton while turning on the CON-
TROL POWER
•
To change a character press the
INCREASE or DECREASE but-
ton
•
To move the cursor to the right
press the UNLOAD button
•
To move the cursor to the left
press the DRY button
•
To delete a character press the
COOL button.
•
Press ENTER when the desired
marquee is displayed
To RESET the computer to the origi-
nal default setting, turn OFF the
computer, press and hold the green
AUX 1 button and turn ON the com-
puter. NOVRAM will appear on the
LCD display. The year, date, time
and minutes may be changed now,
and the shutdown history may also
be cleared. Note: If the history is
cleared the dryer model number
must be RESET or only the bottom
bottom
bottom
bottom
bottom
fan
fan
fan
fan
fan will operate.
Dryer owner and Airstream associates check the Electronic Monitoring Control System.
Dryer owner and Airstream associates check the Electronic Monitoring Control System.
Dryer owner and Airstream associates check the Electronic Monitoring Control System.
Dryer owner and Airstream associates check the Electronic Monitoring Control System.
Dryer owner and Airstream associates check the Electronic Monitoring Control System.
•
Dryer model number
•
Fan delay
•
BPH factor
•
Metering roll monitor disabling
feature
•
Air switch disabling feature
These features are accessed se-
quentially as listed above. Press the
INCREASE or DECREASE buttons
to change a setting. Press the EN-
TER button to move from feature to
feature.
Pressing and holding the RESET but-
ton for five seconds will access the
following programming features:
•
Calendar year setting
•
Calendar month setting
•
Calendar day setting
•
Clock hour setting
•
Clock minute setting
•
Bushel counter reset
•
Batch counter reset
These features are accessed sequen-
tially as listed above. Press the IN-
CREASE or DECREASE buttons to
change a setting. Press the ENTER but-
ton to move from feature to feature.
Important! To activate the controller
after turning on the CONTROL
POWER, press the RESET button.
Setting the DRY, COOL, UNLOAD
and OUT OF GRAIN TIMERS:
•
Press the DRY, COOL, UN-
LOAD or OUT OF GRAIN button
•
Press the MODIFY button
•
Press the INCREASE or DE -
CREASE button to get desired
setting
•
Press the ENTER button when
desired setting is reached
Setting the LOAD and UNLOAD delays:
•
Press the LOAD or UNLOAD but-
ton
•
Press the MODIFY button
•
Press INCREASE or DECREASE
button to get desired setting
•
Press the ENTER button when
desired setting is reached
Pressing the INCREASE and DE-
CREASE buttons simultaneously will
access the following programming
features:
•
Safety circuit shutdown log