Startup & operation for all portable dryers – Grain Systems PNEG-573 User Manual
Page 31

31
120 & 1200 SERIES CONTINUOUS FLOW METERING ROLL SETTINGS
120 & 1200 SERIES CONTINUOUS FLOW METERING ROLL SETTINGS
120 & 1200 SERIES CONTINUOUS FLOW METERING ROLL SETTINGS
120 & 1200 SERIES CONTINUOUS FLOW METERING ROLL SETTINGS
120 & 1200 SERIES CONTINUOUS FLOW METERING ROLL SETTINGS
Initial
Moisture
17%
18%
19%
20%
21%
22%
23%
24%
25%
26%
27%
28%
29%
30%
31%
32%
33%
34%
35%
2 Speed
High
650
550
450
363
272
218
187
163
145
131
119
109
101
093
087
082
077
073
069
2 Speed
Low
187
163
145
131
119
109
101
093
087
082
077
073
069
065
061
057
053
049
045
1 Speed
363
272
218
187
163
145
131
119
109
101
093
087
082
077
073
069
065
062
059
Approx.
Dry Time
18 min.
24 min.
30 min
35 min.
40 min.
45 min.
50 min.
55 min.
60 min.
65 min.
70 min.
75 min.
80 min.
85 min.
90 min.
95 min.
100 min.
105 min.
110 min.
Moisture
Removed
2 pts.
3 pts.
4 pts.
5 pts.
6 pts.
7 pts.
8 pts.
9 pts.
10 pts.
11 pts.
12 pts.
13 pts.
14 pts.
15 pts.
16 pts.
17 pts.
18 pts.
19 pts.
20 pts.
Dry & Cool
These are approximate starting points.
STARTUP & OPERATION FOR ALL PORTABLE DRYERS
STARTUP & OPERATION FOR ALL PORTABLE DRYERS
STARTUP & OPERATION FOR ALL PORTABLE DRYERS
STARTUP & OPERATION FOR ALL PORTABLE DRYERS
STARTUP & OPERATION FOR ALL PORTABLE DRYERS