Pre start checks for all portable dryers – Grain Systems PNEG-573 User Manual
Page 25
![background image](/manuals/277665/25/background.png)
25
PRE START CHECKS FOR ALL PORTABLE DRYERS
PRE START CHECKS FOR ALL PORTABLE DRYERS
PRE START CHECKS FOR ALL PORTABLE DRYERS
PRE START CHECKS FOR ALL PORTABLE DRYERS
PRE START CHECKS FOR ALL PORTABLE DRYERS
MOISTURE CONTROL
MOISTURE CONTROL
MOISTURE CONTROL
MOISTURE CONTROL
MOISTURE CONTROL
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
THERMOSTAT
The Maxon safety shut off valve.
The Maxon safety shut off valve.
The Maxon safety shut off valve.
The Maxon safety shut off valve.
The Maxon safety shut off valve.
ONE SPEED OPERATION
ONE SPEED OPERATION
ONE SPEED OPERATION
ONE SPEED OPERATION
ONE SPEED OPERATION
LOAD AUGER
LOAD AUGER
LOAD AUGER
LOAD AUGER
LOAD AUGER
With the grain supply SHUTOFF,
quickly bump the LOAD AUGER
switch to MANUAL, and see if the
load auger
load auger
load auger
load auger
load auger rotates clockwise as
viewed from the drive end, or coun-
terclockwise if the dryer is a front
load model. If the wet grain supply
auxiliary is wired to the dryer
To check the metering roll
metering roll
metering roll
metering roll
metering roll operation
turn either the LOW speed or HIGH
speed knob clockwise, and the me-
tering roll speed should INCREASE.
Turning either knob counterclockwise
will DECREASE the speed. Make
If using LP gas, make sure the tank
has plenty of fuel and that the tank
does not have a regulator mounted
to it. If using natural gas, make sure
an adequate supply is available.
If using LP gas, slowly OPEN
the main fuel supply valve
fuel supply valve
fuel supply valve
fuel supply valve
fuel supply valve at the
tank. If using natural gas, turn ON
the valve
valve
valve
valve
valve along the supply line.
Then, OPEN the electronic shut off
shut off
shut off
shut off
shut off
valve
valve
valve
valve
valve (Maxon valve), if so equipped,
or OPEN the manual shut off valve
shut off valve
shut off valve
shut off valve
shut off valve
on the dryer to allow fuel flow to the
dryer. Inspect all gas lines and con-
gas lines and con-
gas lines and con-
gas lines and con-
gas lines and con-
nections
nections
nections
nections
nections for possible leaks. Any
Any
Any
Any
Any
gas leaks must be fixed immedi-
gas leaks must be fixed immedi-
gas leaks must be fixed immedi-
gas leaks must be fixed immedi-
gas leaks must be fixed immedi-
ately!
ately!
ately!
ately!
ately!
it should also rotate in the correct
direction at this time. Turn the LOAD
AUGER switch to the AUTO (timed
shutdown) position. The top auger
top auger
top auger
top auger
top auger
and wet grain supply auxiliary
wet grain supply auxiliary
wet grain supply auxiliary
wet grain supply auxiliary
wet grain supply auxiliary
should run for one minute, and then
the dryer will shutdown leaving the
safety shutdown message OUT OF
GRAIN WARNING displayed. Press
the DRYER POWER STOP button
to reset the panel, then press the
START button.
FUEL CHECK
FUEL CHECK
FUEL CHECK
FUEL CHECK
FUEL CHECK
To check 1 SPEED operation place
the UNLOAD switch to the 1 SPEED
setting. Turn up the HIGH speed
metering roll dial until the metering
metering
metering
metering
metering
rolls
rolls
rolls
rolls
rolls start rotating. The bottom au-
bottom au-
bottom au-
bottom au-
bottom au-
ger
ger
ger
ger
ger should rotate counterclockwise
as viewed from the drive end. The
metering roll drive motor
metering roll drive motor
metering roll drive motor
metering roll drive motor
metering roll drive motor should
rotate clockwise as viewed from the
drive end of the gear box
gear box
gear box
gear box
gear box. If the dry
dry
dry
dry
dry
grain take away auxiliary
grain take away auxiliary
grain take away auxiliary
grain take away auxiliary
grain take away auxiliary is wired
to the dryer, it should start and ro-
tate in the proper direction.
To check 2 SPEED operation move
the UNLOAD switch to the 2 SPEED
position, set LOW speed on 200 and
HIGH speed on 600. Slowly turn the
THERMOSTAT until the MOIS-
TURE CONTROL switch light
comes ON. The metering roll speed
is now controlled by the LOW speed
dial. Turning the THERMOSTAT the
other way until the light goes out
leaves the metering rolls
metering rolls
metering rolls
metering rolls
metering rolls controlled
by the HIGH speed dial.
METERING ROLL
METERING ROLL
METERING ROLL
METERING ROLL
METERING ROLL
OPERATION
OPERATION
OPERATION
OPERATION
OPERATION
To check the MOISTURE CON-
TROL THERMOSTAT leave the
UNLOAD switch on 1 SPEED, and
slowly turn down the MOISTURE
CONTROL THERMOSTAT. As the
setting is increased, the indicator
light should come on and the me-
me-
me-
me-
me-
tering rolls
tering rolls
tering rolls
tering rolls
tering rolls should stop operating.
The bottom auger
bottom auger
bottom auger
bottom auger
bottom auger will stop after the
30 second clean out delay, provid-
ing that the dryer is still being held
by the MOISTURE CONTROL
THERMOSTAT. Rotate the MOIS-
TURE CONTROL THERMOSTAT
down to its minimum setting. The
light should go OFF, and the meter-
meter-
meter-
meter-
meter-
ing rolls
ing rolls
ing rolls
ing rolls
ing rolls should restart along with
the bottom auger
bottom auger
bottom auger
bottom auger
bottom auger if it has stopped.
TWO SPEED OPERATION
TWO SPEED OPERATION
TWO SPEED OPERATION
TWO SPEED OPERATION
TWO SPEED OPERATION