2 online and offline parameterization (dtm), Wha-gw, Configuration – VEGA WHA-GW-WIRELESSHART GATEWAY User Manual

Page 46

background image

WHA-GW-*

Configuration

22

1981

2011

-0

7

46

4. Type the IP address of the Gateway into the browser's address field. The factory default

is 192.168 .1.1. If you have already changed the Gateway's IP address, type in the new
IP address. NOTE: In some browsers, you might have to clear the address history first
or add "/index.html" after the IP address.

Depending on the browser you use, some messages might pop up informing you about
the secure connection and the security certificate. In this case, click "OK", "Proceed", or
similar options. Do not cancel the procedure.
A window is displayed asking you for your user name and password (see on page 46).

Entering login data for secure connection

5. Enter your user name and password.

6. Click OK.

You are directed to the Gateway's web interface.

7. Change the parameters as needed. Press Enter to accept a new value. The DTM

parameters described in the following sections also apply to browser-based
configuration.

5.2

Online and offline parameterization (DTM)

The device DTM provides dialogs for offline and online parameterization.

Offline parameterization (not connected to device): If there is no active connection to
the device, only the device data stored in the PACTware project can be edited and
saved to the PACTware project again. You may write the offline data record into the
device as soon as a connection has been established.
To ensure that the data you are editing is up to date, first load the data from the device
when its online and then edit the data offline.

Online parameterization (connected to device): If there is an active connection to the
device, the device data stored in the device can be edited directly (online). Parameter
changes are stored to the device immediately.

The online and offline data are updated using the commands Store to device and Load

from device.

Note!

This section only applies to parameterization via FDT/DTM.