VEGA VEGASON 51V…53V User Manual
Page 14

14
VEGASON 51 V … 53 V
Types and versions
-
Configuration of measuring systems
2
2
4
4
VEGAMET
515V
VEGATRENN
547
2
Ex-area
Not Ex-area
Processings see also product information
"Signal conditioning instruments series 500"
Screened line in case of electro-
magnetic interferences
VEGACONNECT 2
Signal conditioning instrument VEGAMET
515 V with Ex-separator VEGATRENN
548 V Ex in housing type 506
Current outputs
Voltage outputs
Relays
Digital wiring
Fault signals
VEGADIS 50
VEGADIS 50
1 … 2 sensors in Ex-area via separator VEGATRENN 548 V Ex on signal condi-
tioning instrument VEGAMET 515 V
•
Two-wire technology, supply from the signal conditioning instrument. Output
signals and voltage supply via one two-wire line (optionally with
VEGASON 53 four-wire technology)
•
VEGASON 51 … 52:
CENELEC EEx ia IIC T6
VEGASON 53:
StEx Zone 10
•
Digital output signal, two sensors on one line.
•
Measured value indication in the sensor and in the signal conditioning in
strument.
•
Optionally external indicating instrument
(can be mounted up to 25 m separated from the sensor in Ex-area).
•
Adjustment with PC, the signal conditioning instrument or the adjustment
module (can be plugged into the sensor or the external indicating instru
ment).
•
Max. resistance of the signal line 15
Ω
per wire or 1000 m cable length note
the permissible values for capacitance and inductance at the connection
cable (see approval certificate of the separators)