Gas sampling and gas conditioning technology
6-1.1.7-ME
W A R N I N G !
It is important to provide protection for persons against contact
with life parts (e.g. electrical connections, eventually motor wind-
ings) or moving parts (e.g. fan).
The pumps are not protected against effects from water. If applicable, respective protection measures
must be taken before starting the pump.
W A R N I N G !
Aggressive medium is possible.
Wear protective glasses and appropriate protective clothes during
disassembly, repair or cleaning the pump!
The pumps must only be used for their intended purpose.
N O T E !
Components to be connected to the pump must be designed
according to the pneumatic performance of the pump (see tech-
nical data).
Take care that safety regulations are observed when connecting
the pump to the power supply.
Specific safety instructions concerning the lifted medium are to
be observed.
9
TECHNICAL DATA
Diaphragm pump
MP47-Z-
BPR150-Viton
MP47-Z-
BPR150-Viton
MP47-Z-
BPR150-Kalrez
MP47-Z-
BPR150-Kalrez
Part No.
02 P 1160
02 P 1160a
02 P 1165
02 P 1165a