beautypg.com

M&C TechGroup MV3_2-H Series Data sheet User Manual

Electrically heated valves series v3/2-h, mv3/2-h, Special features, Application

background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

11.3

Embracing Challenge

ƒ

ƒ

Electrically heated up to max. 180 °C

ƒ

ƒ

Integrated thermostat

ƒ

ƒ

Status contact output

ƒ

ƒ

Sure connection technique

ƒ

ƒ

No cold bridges

ƒ

ƒ

Easy to maintain

ƒ

ƒ

Option ball valve with position identifi-
cation

Special Features

Electrically heated valves
series V3/2-H, MV3/2-H

Version V3/2-H /PE, 3/2-way ball valve, electrically heated up
to 180 °C, Version MV3/2-H, 3/2-way solenoid valve, electrically
heated up to 180 °C

V3/2-H

Application

In analysis technique, often temperatures

must be kept above the sample gas dew

point. Therefore, it is absolutely necessary to

avoid cold bridges. In order to ensure this,

the temperature regulated M&C three-way

valves V3/2-H and MV3/2 H are used for the

cut-off or switching-over of sample gases and

test gases up to an operating temperature of

180 °C.

Description

The M&C electrically heated valves are fixed

on a mounting plate, decoupled from heat

and covered with an insulated enclosure. The

heater consists of a heating element with

high capacity. The temperature is adjustable

on the integrated thermostat up to 180 °C

with high temperature limiter and low tem-

perature alarm.
The heat insulated enclosure with a bushing

for the dial thermometer is equipped with

quick acting bentlever closures. The connec-

tion box with integrated thermostat is installed

outside the enclosure on the mounting plate.

Version V3/2-H/PE has got an additional con-

necting box for the contact output of the

position identification. The power supply for

the solenoid valves version MV3/2-H is 24V

DC and the additional connecting box is

installed on the mounting plate. In order

to prevent cold bridges, the connecting fit-

tings are heated by means of thermal con-

ducting jaws. The electrically heated sample

lines type 3/4/5-N/M/H – see data sheet

3.1 – are fixed with mounting brackets.

Technical specifications and illustrations are without