Special Features

Gas Sample Probe Series SP®

Version SP2000, SP2000-H, SP2300-H, SP2400-H

SP2000-H

Application

The M&C sample probes version SP2000...,

SP2300-H and SP2400-H are used for con-

tinuous extraction of gases from dust loaden,

hight temperature and/or humid processes.

Description

The sample probes are designed for easy

installation, reliable operation and trouble

free maintenance. They are versatile in appli-

cation and depending on the task to be

performed various sample tubes or pre-filters

(see data sheet 2.14 and 2.17), not included in

the scale of delivery, can be simply screwed

into the probe (G 3/4» thread).
The filter element (ceramic is standard,

others optional) with a large surface area

and high capacity is located in the external

housing.
The design offers little or no stag-

nant space external to the process. The

probes are designed so that changing

a filter element does not involve the use

of tools. In this operation neither the sam-

ple probe tube nor sample line need to

be removed, thus avoiding contamination

of the clean gas path and maintaining the

integrity of the system.
The sample tube can be cleaned, washed or

rodded-out from outside the process. The

special design of the heating element of the

SP2000/2300/2400-H (with protective hood)

permits controlled heating of the complete

filter housing, including the mounting flange

up tp 180 °C (Version /H320 up to 320 °C).

This ensures reliable operation external to the

process preventing the temperature falling

below the dew-point.
The temperature of the standard probe is

controlled by an integral compact design

capillary sensor thermostat with an excess

temperature limit switch and an alarm func-

tion for temperature failure. The probe can be

provided with test and reference gas facilities.

Depending on the gas composition, it is pos-

sible that the standard material of the probe

body (stainless steel 316) will not be suffi-

ciently corrosion resistant. In this case probe

SP2300-H made of PTFE or SP2400-H made of

Titanium should be used.