M&C TechGroup FM10 Data sheet User Manual
Flowmeter series fm, Version fm1, fm10, Special features
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
9.1
Embracing Challenge
High chemical resistance
For gases and liquids available
Easy dismantling and cleaning
Also with high precision needle valve
Also for high temperatures
Special Features
Flowmeter series FM®
Version FM1, FM10
FM10
Application
The M&C flowmeters – type FM1 and FM10
– which are corrosion-resistant are used for
controlling the flow in case of aggressive
gases and liquids. The flow tube is delivered
according to your specific data, e.g. medium,
temperature, pressure.
Description
The M&C flowmeters FM1 and FM10 consist
of a glass tube (the inside is conical and
becomes enlarged in the upper sector) in
which the floating ball can move.
The substance flows through the tube from
the below part to the upper part so that the
floating ball is raised. It arises a gap between
the tube wall and the substance and creates
an equilibrium. Each level of the floating ball
corresponds to a certain flow rate which is
shown on the scale.
The sealing and connecting parts are con-
structively reduced and consist only of in- and
outlet connection. All medium contacted
parts are made out of PTFE and glass. The
flowmeter is configurated in such a way that it
can easily be dismantled and cleaned.
The flowmeter FM10 is equipped with a nee-
dle valve in the inlet which enables you to
adjust the flow rate with high precision.
•
For automatic flow control the control
unit types FA... are used. Please see sepa-
rate data sheets 9.4 / 9.5 / 9.6
•
For connecting the tubes, a special pro-
gramme is available. Please see separate
data sheet 11.5
Technical specifications and illustrations are without
obligation, subject to modifications. 10.99/06.06